Diablo EZReporter 1.0
Natural Gas Analysis Module
The optional Natural Gas Analysis (NGA) module is designed to perform Natural
Gas / Refinery Gas heating value and related calculations. The results from these
calculations are available for reporting, monitoring, trend plotting, and
exporting through the base module. The features present in the NGA module
include:
- Standard GPA/ASTM Calculations: Calculates Dry/Saturated/Wet Gross
Heating Value, Real Relative Density, Gas Compressibility factor, GPM value,
and Wobbe Index using GPA 2172-09 and ASTM D3588-98 (2003) standard
calculations.
|
Individual Component
Results
(Dry, Saturated, and Wet*) |
| Component Normalized Mole% |
| Component Normalized Weight% |
| Component Gross Heating Value |
| Component Relative Density (Gas) |
| Component GPM |
| Component Compressibility |
| Component Molecular Weight |
|
Total Results
(Dry, Saturated, and Wet*) |
| Total Raw (unnormalized) Amount |
Water Mole Fraction and Mole%
(Saturated at base conditions or at a specified flowing temp. and
pressure) |
| Gross Heating Value (Ideal and Real) |
| Relative Density of Gas (Ideal and Real) |
| Compressibility (Z) factor |
| Total GPM |
| Total Molecular Weight |
| Wobbe Index |
| * "Wet" results can either be based on an actual
measured water mole% of a partially saturated gas or for a
water-saturated gas at a specified flowing temperature and
pressure. |
- Physical Properties can be Easily Customized: The component list
is completely customizable. Components can be added to or deleted from the
component list, and calculation factors (Heating Value, Molar Mass Ratio,
Summation Factor, and GPM Volume Factor) can be updated by the user either
manually or using one of the standard physical property tables included in
the software.

- Standard Physical Property Tables: Standard component physical
property tables are provided for the GPA 2145-03 and GPA 2145-09 Standards,
and the GPSA Engineering Data Book (12th Edition, 2004).
- Export to Text File: You can create custom export templates
to save NGA results to text files for import into flow and measurement
systems like Flow-Cal and PGAS.
- Monitor Results with Alarms: You can use "Monitored
Parameters" to set up alarms for critical parameters like the total
un-normalized mole%.

- Disable NGA Module: The NGA calculations can be disabled if you want to use the software only
for general reporting, monitoring, and exporting of Agilent ChemStation, EZChrom or Cerity
analysis results.
See Also: EZReporter Base
Module, EZReporter Results Database Module, EZReporter
Home Page
|